News

 
  1. Public Holiday and Changed Opening Hours

    16 May 12 Between 17–18 May RTI Headquarter is closed.
    RTI Inc is open as usual.

  2. New Software Release – 2012.05A

    11 May 12 Piranha and Barracuda Latest Update

    Released: May 11, 2012

    Ocean: 2012.05.09.82
    QABrowser: 4.2B
    oRTIgo: 6.5A
    CT Dose Profile Analyzer: 4.1A
    Firmware: 2012.2A

  3. Mammo12

    One Shot HVL for Mammography

    07 May 12 One shot HVL for mammography is now available to all new Piranhas of version 2 or higher.
    One shot HVL is possible both if you are using Ocean or QA Browser, with or without compression paddle.

    All Piranhas (version 2 or higher), which are in for re-calibration, will get the one shot HVL feature.

  4. Time for Calibration - Schedule Yours Now

    06 May 12 Please take five minutes to schedule your coming calibration with the RTI Service department.

Show all news

Barracuda

Barracuda

A Flexible Arrangement

The Barracuda is an "all-in-one" X-ray multimeter for QA. The Barracuda can be configured to meet each user's specific need and requirements. It is easily upgradeable when the needs increase and new technology becomes available. The cabinet can house up to six different modules.

The Barracuda can measure on all modalities; R/F, mammography, fluoroscopy, pulsed fluoroscopy, dental, panoramic dental and CT systems. Auto Compensation ensures that data is accurate and no manual corrections of measured kVp and dose readings are required. The Barracuda is compact, the setup time is short, and it is easily transported in its carrying case.

Barracuda is a modular system and can be configured in many different ways. A number of add-on probes are available, for example: mAs probes, ionization chambers, dose detectors and light detector. If additional probes are used, the required electrometer module can be easily added in minutes.


Multi-Purpose Detector

The Multi-Purpose Detector (MPD) is a dedicated detector for the Barracuda system. It can be used for all modalities - from mammography at 18 kVp to conventional radiography or CT. The MPD measures the following parameters: kVp, time, dose, dose rate, dose/pulse, pulse rate, total filtration (with one exposure), HVL (with one exposure), kV and dose rate waveforms. Even for small C-arm units the kVp can be measured reliably, due to the MPD's sensitivity.

Modular System - EMM

The Barracuda can be equipped with one or several electrometer modules (EMMs). Measuring charge and current from a probe. The calibration factor for the detector or probe is used to calculate the measured value, for example dose and dose rate. Six different electrometer modules are available, two without bias and three with bias.

Scatter and Leakage

EMM-BiasW is ideal for use with solid state detectors as well as ion chambers. The EMM-BiasW has a wide measuring range and the high sensitivity with the R100B detector of 1 nGy/s enables measurement also of scatter and leakage radiation in the x-ray room.

PC Software

The Barracuda can also be used with the Ocean PC Software. The Ocean software connects to the Barracuda, measured data and waveforms are automatically collected and stored. The oRTIgo software has a large number of templates for different tests; accuracy, reproducibility, linearity, HVL, AEC, and much more. Pass/Fail criteria can be defined, reports can be generated and printed.

With Ocean you have a tool that will help you in your daily work. It will help you to get organized – regardless if you are checking an X-ray system or a monitor. Reduce mistakes and increase your efficiency by adding pop-up hints or instructions and pictures. This will simplify and align the work for you and your colleagues. There really seems to be no limits to where Ocean can take you.

Graphical Display with Waveforms

The Barracuda uses a graphical display (QABrowser) to display measured data. Both measured values and waveforms are instantly displayed after each exposure. Up to six measured values and three waveform are shown at the same time. The graphical display also provides an intuitive user-interface that makes it very simple to setup the meter for different type of measurements. The display connects wireless via Bluetooth or via cable to the Barracuda.

Rad/Flu/Dent/CT
Range Inaccuracy
35 – 155 kVp ±1.5 %
0.1 ms – 2000 s  ±1 % or ±0.5 ms
1 – 65535 pulses  ±1 pulse
30 nGy – 1000 Gy ±5 %
4 µR – 100 kR ±5 %
15 nGy/s – 450 mGy/s ±5 % or ±7 nGy/s
1.7 µR/s – 50 R/s ±5 % or ±0.8 µR/s
0.1 mR/min – 3000 R/min ±5 % or ±0.05 mR/min
1.5 – 38 mm Al Total Filtr. ±10 % or ±0.3 mm
1.2 – 14 mm Al HVL ±10 % or ±0.2 mm
Mammography
Range Inaccuracy
18 – 49 kVp (Mo/Mo) ±0.7 kV
0.1 ms – 2000 s  ±1 % or ±0.5 ms
1 – 65535 pulses  ±1 pulse
70 nGy – 2000 Gy ±5 %
8 µR – 200 kR ±5 %
15 nGy/s – 750 mGy/s  ±5 % or ±0.04 µGy/s
17 µR/s – 86 R/s ±5 % or ±4 µR/s
1 mR/min – 5100 R/min ±5 % or ±0.3 mR/min

Specifications are based on the most popular Barracuda models. May not be valid for some. Please check with your local representative for more details.

Calibrations for beam qualities

Mo/Mo, Mo/Rh, Rh/Rh, Rh/Al, W/Al, W/Rh, W/Ag

 
 

Please enter your user name and password below.