News

 
  1. RTI Electronics AB is Looking for New Employees

    26 Jan 12 Would you like to be part of developing the medical technology products and markets of the future? RTI Electronics is growing and is now looking for new co-workers who want to be part of shaping the future in an exciting industry.

  2. RTI Electronics, Inc. has Moved

    02 Jan 12 RTI Electronics, Inc. has moved to larger location with lots of space to grow. Starting Tuesday, January 3, 2012 you can find RTI Electronics, Inc. at:

    33 Jacksonville Road
    Building 1
    Towaco, NJ 07082

    RTI Inc's phone numbers and contact information are the same for your convenience.

  3. Merry Christmas 2011 from RTI

    All the Best for 2012

    22 Dec 11 We wish to thank our customers and users for a fruitful 2011, wish you a really nice Christmas, and the best for 2012. Monday 26 December RTI Headquarters is closed.

Show all news
Chamber Adapter

Magna 1 cc

Magna 1 cc

Designed Especially for Mammographic Measurements

The Magna 1 cc ionisation chamber is designed especially for mammographic dose and dose rate measurements. However, it has an excellent energy response and can also be used for radiographic applications. The Magna Ion Chamber is the ideal choice for two reasons; Evaluations of Magna chambers show an average response is within ± 1% over an extended mammography range of 20-40 kVp (HVL of 0.15 mm to 0.73 mm Al). All mammographic mean glandular dose tables are based on in air measurements. MAGNA's air equivalent construction makes it ideally suited for in air exposure measurements of mean glandular dose. The Magna 1 cc will be delivered in a durable case for its best protection.

Magna 1cc together with Barracuda

The Magna 1cc can be connected directly to the Barracuda (via a bias electrometer module EMM-Bias module). It can be used especially for mammography applications when an ion chamber is preferred instead of a solid-state detector.

Magna 1cc together with Solidose 400

Magna 1cc can also be connected directly to the Solidose 400 - no adapter cable is needed. It can be used especially for mammography applications when an ion chamber is preferred instead of a solid-state detector.

 


General
  • Energy dependence Within ±1 % for HVL of 0.15 mm to 0,73 mm Al
  • Within ±2 % for 20 to 150 kVp
  • Construction Air equivalent conductive plastic
  • Sensitivity 38 nC/Gy or 0.33 nC/R
  • Collecting Volume 1 cm3
  • Ventage Yes
  • Leakage < 50 fA
  • Typical Bias 300 V DC
  • Window Kapton conductive film + mylar protective film
  • Cable length 2 m
  • Connector Triax LEMO
Ranges with Piranha (Chamber Adapter required)
Dose Rate 25 µGy/s to 2.5 Gy/s 
Inaccuracy ±6 % or ±0.025 mGy/s

Ranges with Barracuda (with EMM-Biasw)
Dose  150 nGy-at least 2 MGy ±5 %
17 µR-200 MR
Dose rate  5 µGy/s-250 Gy/s ±5 %
30 MR/min-1500 kR/min

 

Ranges with Solidose 400
Dose 13 µGy -200 kGy ±5 %
1.5 mR-20 MR
Dose rate  125 µGy/s-390 Gy/s ±5 %
0.85 R/min-2.6 MR/min


 
 