News

 
  1. Public Holiday and Changed Opening Hours

    16 May 12 Between 17–18 May RTI Headquarter is closed.
    RTI Inc is open as usual.

  2. New Software Release – 2012.05A

    11 May 12 Piranha and Barracuda Latest Update

    Released: May 11, 2012

    Ocean: 2012.05.09.82
    QABrowser: 4.2B
    oRTIgo: 6.5A
    CT Dose Profile Analyzer: 4.1A
    Firmware: 2012.2A

  3. Mammo12

    One Shot HVL for Mammography

    07 May 12 One shot HVL for mammography is now available to all new Piranhas of version 2 or higher.
    One shot HVL is possible both if you are using Ocean or QA Browser, with or without compression paddle.

    All Piranhas (version 2 or higher), which are in for re-calibration, will get the one shot HVL feature.

  4. Time for Calibration - Schedule Yours Now

    06 May 12 Please take five minutes to schedule your coming calibration with the RTI Service department.

Show all news
Chamber Adapter

DCT10 Pencil Ionization Chamber

DCT10 Pencil Ionization Chamber

Ionization Chamber for CTDI Measurements

The DCT10 RS is rugged, cylindrical pencil shaped air ionization chamber for CTDI measurements. The CT probe is intended for measuring and monitoring the exposure output level of CT scanners in a phantom or in air. CT dose index, CTDI, can be measured in accordance with IEC 61223-2-6.


DCT10 and Piranha

The DCT10 RS can be connected via Chamber Adapter to the Piranha to measure CT dose.

Ranges with Piranha (Chamber Adapter required)
Dose Rate 0.8 mGycm/s to 8 Gycm/s
Inaccuracy ±6 % or ±0.08 mGycm/s

 

DCT10 and the Barracuda

The DCT10 RS can be connected directly to the Barracuda (via an electrometer module supporting bias) to measure CT dose. Barracuda has built-in functions to simplify measurements of CTDI (CT dose index).

Measuring ranges with Barracuda (with EMM-Biasw)
Dose 40 nGym-350 kGym
4 µGycm-35 MGycm

Dose rate 1.6 µGym/s-70 kGym/s
160 µGycm/s-7kGycm/s
Inaccuracy ±5 % or 16 µGycm/s
 
DCT10 and the Solidose Family

The DCT10 RS can be connected directly to the Solidose 400 to measure CT dose.

Measuring ranges Solidose
Dose 20 µGycm - 400 kGycm ±5 %
2.3 mRcm - 46 MRcm
Dose rate 200 µGycm/s - 600 Gycm/s ±5 %
1.4 Rcm/min - 4 MRcm/min

General Specifications DCT10 Pencil Ionization Chamber
Connector type
LEMO triaxial
Cable
2 m, low noise triaxial
Active volume
4.9 cm3
Active length
100 mm
Inner diameter
8.0 mm
Typical leakage
±4 fA
Radiation quality 80 - 150 kV
Sensitivity
40 nC/Gycm or 400 nC/Gy
  0.35 nC/Rcm or 3.5 nC/R

Article Nr: 9705111-00

 
 