News

 
  1. assets/News/Juli-2010/_resampled/SetWidth190-South-2.jpg

    RTI Electronics Strengthening its Position in South America

    23 Jul 10 We are now pleased to present three new distributors in South America.

  2. assets/News/Juli-2010/_resampled/SetWidth190-Picture-T20-034.jpg

    Important Solid State Detector Accessories by RTI Electronics

    23 Jul 10 If you own an RTI Piranha or Barracuda multi-meter, you may want to consider adding two special solid state detectors specially developed by RTI Electronics.

  3. Exciting Innovations at AAPM

    14 Jul 10 RTI's display 756 will feature some of the most exciting X-ray QA products.

  4. assets/About_Us/Certification-and-Approval/_resampled/SetWidth190-Accred-2021.png

    Quality-Assured Laboratories at RTI Electronics AB

    14 Jun 10 This accreditation is a guarantee that our assignment is carried out impartially, fairly and based on internationally accepted standards. It provides third-party assurance that we have the quality management system to ensure all of our calibrations to be consistently of the highest quality.

  5. assets/Accessories/MAS-1-o-2/_resampled/SetWidth190-MAS-1.png

    Redesigned and Improved MAS-1

    02 Jun 10 This month RTI releases the new redesigned MAS-1.

Show all news
Detector Extender

Piranha Dose Probe

Piranha Dose Probe

For Low dose Rate Measurements with the Piranha

The Piranha Dose Probe is specially designed for low dose rate measurements with the Piranha. The detector is small to minimize interference with the X-ray systems’ AEC. The Piranha Dose Probe is ideal for field service situations since the detector is well protected from damages by the metal housing. Since it is a solid-state detector, it needs no corrections for temperature or pressure, or bias voltage.

Fluoroscopy

The Piranha Dose Probe is small and has a fast response which makes it ideal for pulsed fluroscopy. It can detect the individual pulses, determine pulse rate and show waveforms even at the highest pulse rates used on modern fluoroscopy systems and be used both for continuous and pulsed fluroroscopy. This is not possible with ionization chambers since their response is too slow to resolve individual pulses.

The Piranha Dose Probe supports the Piranha ADI (automatic detector identification) system. All information about the probe is stored in a memory inside the probe. When connected, the Piranha automatically identifies the probe and makes all necessary adjustments without any need for interaction from the user. The Piranha ADI system also gives full interchangeability of probes between different Piranha systems using the same type of probes.


Light green triangle: 3 mm Al + 2.0 mm Cu
Dark green square: 3 mm Al + 1.5 mm Cu

Specifications
Type  R100B
Sensitivity  55 µC/Gy
Size  20 x 45 x 7.4 mm, 0.79" x 1.8" x 0.29"

Weight 85 g (3 oz)
Active detector area 10 x 10 mm, 0.39" x 0.39"
Cable length 2.0 m (6.6 ft)
Connector  Piranha type with automatic detector identification
Dose range  0.1 nGy - >100 kGy

12 nR - >11000 kR
Dose rate range  4 nGy/s - 76 mGy/s

1.6 mR/h - 31 kR/h
Dose per pulse  1 nGy/pulse - 3 kGy/pulse

12 nR/pulse - 340 kR/pulse
Backscatter
None
 
 