News

 
  1. assets/News/Juli-2010/_resampled/SetWidth190-South-2.jpg

    RTI Electronics Strengthening its Position in South America

    23 Jul 10 We are now pleased to present three new distributors in South America.

  2. assets/News/Juli-2010/_resampled/SetWidth190-Picture-T20-034.jpg

    Important Solid State Detector Accessories by RTI Electronics

    23 Jul 10 If you own an RTI Piranha or Barracuda multi-meter, you may want to consider adding two special solid state detectors specially developed by RTI Electronics.

  3. Exciting Innovations at AAPM

    14 Jul 10 RTI's display 756 will feature some of the most exciting X-ray QA products.

  4. assets/About_Us/Certification-and-Approval/_resampled/SetWidth190-Accred-2021.png

    Quality-Assured Laboratories at RTI Electronics AB

    14 Jun 10 This accreditation is a guarantee that our assignment is carried out impartially, fairly and based on internationally accepted standards. It provides third-party assurance that we have the quality management system to ensure all of our calibrations to be consistently of the highest quality.

  5. assets/Accessories/MAS-1-o-2/_resampled/SetWidth190-MAS-1.png

    Redesigned and Improved MAS-1

    02 Jun 10 This month RTI releases the new redesigned MAS-1.

Show all news

Computed Tomography

Computed tomography - in general

Computed Tomography is an area that has grown exponentially during the past years. Since CT is a very fast and efficient alternative for examinations, its applications are increasing. For example, a CT may be used to perform a fast scan on trauma patients. However, with good pictures comes higher doses and it is very important to verify that the patient doses are kept within acceptance limits. 

Checking the CT system

More and more advanced systems are developed and it may be hard to keep up with the pace and really understand what comes out from the CT.

To help you along the way you can use the Piranha or the Barracuda MPD to perform the measurements of kVp, time, total filtration and HVL. For the CT dose measurements, we recommend that you use our unique solid state CT Dose Profiler.

The CT Dose Profiler can measure the CTDI just like a pencil ion chamber but it has several advantages to the ionization chamber solution. Since the X-ray fields of the CT systems are getting wider, the 10 cm pencil chamber is no longer enough to capture the whole dose contribution. With the CT Dose Profiler you capture the dose profile and see what the output looks like.

 
 